Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Med. infant ; 30(2): 217-222, Junio 2023. ilus, tab
Article in Spanish | LILACS, UNISALUD, BINACIS | ID: biblio-1444540

ABSTRACT

El monóxido de carbono es un gas altamente tóxico que se origina principalmente por la combustión incompleta de combustibles fósiles. La intoxicación presenta síntomas inespecíficos que solapan otras patologías y por lo tanto es indispensable la confirmación mediante la medición de la carboxihemoglobina en sangre. El laboratorio incorporó la determinación en el informe del estado ácido base a partir de octubre del 2018, debido a que previamente el médico debía solicitarla frente a la sospecha de una intoxicación. El objetivo del trabajo fue evaluar si esta medida implementada por el laboratorio contribuyó a mejorar el diagnóstico de intoxicación por CO, analizar las características de los pacientes con COHb mayor o igual a 5% y definir un valor de reporte inmediato para la COHb. El 46% de los casos con COHb mayor o igual a 5% no se relacionaban con una intoxicación y/o exposición a CO. De los casos de intoxicación se encontró que el 77% fueron diagnosticados a partir de la sospecha médica y un 23% por hallazgo del laboratorio. Se concluyó que es de mucha utilidad el rol del laboratorio en detectar aquellos casos que no fueron evidentes clínicamente. Existen ciertas patologías como las oncológicas o la enfermedad de Wilson donde se vieron valores elevados de COHb sin presentar intoxicación y se definió finalmente, como valor de reporte inmediato 7% para la COHb. (AU)


Carbon monoxide is a highly toxic gas that originates mainly from incomplete combustion of fossil fuels. Intoxication causes nonspecific symptoms that overlap with other conditions and, therefore, confirmation by measuring blood carboxyhemoglobin is essential. The laboratory incorporated the measurement in the acid-base status report as of October 2018, as it was previously required to be requested by the physician in case of suspected intoxication. The aim of this study was to evaluate whether this measure implemented by the laboratory contributed to the improvement of the diagnosis of CO intoxication, to analyze the characteristics of patients with COHb greater than or equal to 5% and to define an immediate reporting value for COHb. Overall, 46% of the cases with COHb greater than or equal to 5% were not related to CO poisoning and/or exposure. Of the cases of intoxication, 77% were diagnosed based on medical suspicion and 23% on laboratory findings. It was concluded that the laboratory has a useful role in detecting cases that were not clinically evident. There are certain diseases including different types of cancer or Wilson's disease where elevated COHb values were seen without intoxication and finally, 7% for COHb was defined as the immediate reporting value (AU)


Subject(s)
Humans , Infant, Newborn , Infant , Child, Preschool , Child , Adolescent , Carboxyhemoglobin/analysis , Carbon Monoxide Poisoning/diagnosis , Carbon Monoxide Poisoning/blood , Clinical Laboratory Techniques/instrumentation , Inhalation Exposure/analysis , Retrospective Studies , Diagnosis, Differential
SELECTION OF CITATIONS
SEARCH DETAIL